TM 11-5815-602-10
EE161-DM-OPl-010/E154UGC74
TO 31W4-2UGC74-1
B--Before Operating D--During Operating WWeekly MMonthly
Item Interval
Procedures
Equipment Is Not
Item to be Check for and have repaired for
BDW
M i n s p e c t e d adjusted as necessary
Ready/Available If:
No.
NOTE
Refer to appropriate
paragraphs for assistance.
Mounting
1
Check the mounting of the terminal
to ensure it is secure.
Dust cover
a. Inspect the dustcover alignment
2
against the chassis assembly. Check
the condition of the four front cover
latches. They should open with
b. With the dustcover lowered, in-
spect the rubber seal on the chassis
assembly for wear, gouges, tears or
missing sections.
Unserviceable cables
Inspect for undue strain caused by
Primary
3
or connectors prevent
twisting or tangling which would
power
ing the terminal from
cause damage to the cables or
source
being operated.
connectors as the terminal is being
cables and
extended from or returned into the
connectors
outer case.
Excessive dirt, dust,
a. Release the combination case
Case
4
grease, moisture, or
latches and carefully extend the
interior
fungus would prevent
terminal from the outer case.
he terminal from
(1) The terminal should slide
operating properly, or
smoothly out from the outer case to
if operated, would
the stop locks.
cause possible
(2) If the terminal hangs or fails to
damage or malfunc-
to slide smoothly, check for dirt,
tioning of the ter-
burrs, or other obstructions.
minal.
b. Clean the case interior of oil,
dust, grease, moisture or fungus.
c. Clean the interior of the terminal
with a long handle sash or camel's
hair brush.
5
Print drum
Message copy is
Check the quality of the print drum
printing
printing by inspecting the message
unreadable.
copy for readability.
2-42