TM 11-5805-384-30
2-18. REPLACEMENT OF FIXED ELECTROLYTIC CAPACITOR.
This task covers:
1. Removal
2. Installation
Personnel Required
INITIAL SETUP
One technician
Tools
Equipment Condition
Tool Kit, Electronic Equipment TK-100/G
Telephone set shell assembly removed. (para
Materials/Parts
2-9)
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
1.
Baseplate assembly.
Nut (1)
Using 114-inch wrench, remove
2.
Capacitor
Positive lead (2) and plastic sleeving (3)
Using needle nose pliers, slide sleeving away
from terminal.
NOTE
The positive lead is closest to positive sign (+).
WARNING
Observe polarity marked on capacitor. Failure to
do so can cause injury.
3.
Hookswitch
Terminal (4)
Tag terminal.
4.
Capacitor
Negative lead (5)
terminal.
INSTALLATION
1.
Capacitor
Negative lead (5)
Using soldering iron, solder to terminal.